Pediatric Researchers Establish 3D Echocardiography Reference Curves for
Pediatric researchers have established a computational framework and open-source software tool that generates normalized reference volume-time curves and rate-of-change curves for the human left ventricle using three-dimensional echocardiography datasets gathe
Illustrative imagePediatric researchers have established a computational framework and open-source software tool that generates normalized reference volume-time curves and rate-of-change curves for the human left ventricle using three-dimensional echocardiography datasets gathered from a cohort of 371 healthy infants, children, and adolescents. In an investigation published in Pediatric Research, the investigative team demonstrated that volume changes tracked across the complete course of the cardiac cycle provide detailed temporal and volumetric insight into both systolic and diastolic performance. By transforming raw three-dimensional echocardiographic data into continuous, standardized waveforms and applying formal mathematical distance metrics, the approach enables clinicians and researchers to plot individual patient recordings directly against established normative reference distributions. This method allows immediate visual inspection of functional discrepancies alongside quantitative statistical classification using standard deviation scores. The resulting analytical framework addresses a long-standing methodological limitation in pediatric cardiology, where substantial physiological variations in heart rate, cardiac cycle duration, and absolute chamber volumes across developing age groups have previously hindered the construction of reliable normative reference curves.
Clinical evaluation of left ventricular performance remains essential for the diagnosis, therapeutic monitoring, and ongoing medical management of children presenting with congenital or acquired cardiac disease. Conventional diagnostic practice has predominantly relied on discrete parameters such as left ventricular ejection fraction and stroke volume to gauge systolic capacity. However, because these single indices capture ventricular dimensions at only two isolated time points of the cardiac cycle, end-diastole and end-systole, they necessarily omit complex continuous dynamics including myocardial shortening, wall thickening, and chamber torsion. Furthermore, standard non-invasive measures of diastolic filling, which frequently rely on mitral valve inflow Doppler, tissue Doppler patterns, and left atrial volume measurements, were primarily developed and validated in adult cohorts and often fail to reflect diastolic alterations accurately in younger pediatric populations. To overcome the diagnostic blind spots inherent in isolated temporal markers, investigators have long recognized the theoretical value of volume-time curves generated non-invasively through three-dimensional echocardiography, which record continuous volumetric alterations and permit mathematical calculation of instantaneous emptying and filling velocities.
To build a robust normative reference baseline, the research consortium gathered three-dimensional echocardiographic recordings from a multicenter prospective study originally conducted between April 2011 and November 2013 across multiple participating medical centers. The normative sample comprised 371 healthy subjects ranging from birth through 18 years of age, all presenting with documented normal cardiac anatomy and normal functional performance. The original study protocol operated under local ethics institutional review committee approval under registration number 226/06 and secured appropriate ethical permissions from all institutional boards, adhering strictly to German legal requirements and the ethical tenets of the Declaration of Helsinki. Informed written consent was systematically acquired from legal guardians or directly from participants who had reached 18 years of age. Datasets from these 371 healthy children and adolescents provided the empirical foundation required to model normalized reference curves alongside their corresponding first derivatives, establishing a standardized baseline representative of healthy ventricular behavior across growth and development.
Echocardiographic image acquisition for the normative pediatric cohort was carried out using dedicated Philips iE33 ultrasound machines fitted with matrix-array transducers, specifically the X5-1 or X7-2 probes. Imaging specialists captured full-volume three-dimensional echocardiographic datasets using an apical approach aligned with established standardized pediatric imaging recommendations. Each full-volume acquisition was reconstructed from four to seven electrocardiogram R-wave-triggered subvolumes, performed during end-expiratory breath-holding whenever patient cooperation allowed. For subsequent clinical comparison cohorts, examinations were conducted using either Philips iE33 or Philips Epiq ultrasound systems. Acoustic datasets recorded with the iE33 platform were analyzed using Philips QLab Version 9.0 3DQ Advanced analysis software or TomTec 4D LV-Analysis versions 3.1 or 3.3. Left ventricular alignment was adjusted across three apical perspectives to achieve optimal chamber visualization, after which automated border detection traced endocardial contours at maximal end-diastolic volume with selective manual adjustment, ensuring ventricular trabeculae and papillary muscles were incorporated within the cavity volume before tracing minimal end-systolic dimensions. Raw volumetric series containing measured cavity volumes in milliliters and discrete timestamps in milliseconds were subsequently exported as text files for centralized algorithmic processing.
Raw exported time-series curves required systematic mathematical conditioning to resolve irregular sampling intervals and physiological variations before direct comparisons could be performed. Using custom in-house software developed in Python, the researchers initially interpolated all exported volumetric data points to uniform, equidistant steps of 1 millisecond. Each reconstructed curve was then shifted along the temporal axis so that the exact moment of maximal left ventricular chamber volume, signifying end-diastole, was anchored at time zero. Because raw interpolated records often spanned a temporal duration shorter than the entire physiological R-R interval recorded simultaneously on surface electrocardiography, the authors implemented curve-fitting routines using a third-order Fourier series formulation. This mathematical model reconstructed missing segment data while enforcing smooth, periodic representations across the entire cycle, estimating key harmonic parameters through a least-squares fitting algorithm guided by the fundamental frequency derived directly from total cycle duration.
Once continuous volume-time curves were established through Fourier series modeling, the researchers analytically differentiated each fitted function to obtain its instantaneous first derivative, denoted as dV/dt. This derived curve represents the rate of volume change over time, allowing precise mathematical extraction of critical dynamic features such as peak emptying rate during ventricular systole and peak filling rate during ventricular diastole. Normalization was subsequently performed across two distinct axes to eliminate confounding influences arising from disparate baseline body sizes and shifting heart rates. The computed volumes along the fitted curve were normalized by dividing each instantaneous volume value by the maximum end-diastolic volume of that specific cycle. Simultaneously, the temporal progression was normalized against the total R-R interval duration. The entire analytical processing pipeline was compiled into an open-source graphical user interface programmed in Python, which the authors made publicly accessible through the Zenodo digital repository with accompanying sample datasets to support external computational reproducibility.
To rigorously evaluate how an individual patient curve behaves relative to healthy physiological patterns, the researchers introduced two independent mathematical distance metrics, termed DVTC and DdVdt. The first metric, DVTC, calculates the total area under the curve formed after subtracting the patient’s normalized volume-time curve from the median volume-time curve of the 371 healthy subjects, visually representing the cumulative volumetric discrepancy across the standardized cardiac cycle. The second metric, DdVdt, computes the dynamic time warping distance between the patient’s normalized first-derivative curve and the normative cohort’s median derivative curve using the dtw computational library in RStudio. Dynamic time warping aligns time-dependent signals that may vary in velocity, where lower computed distance values reflect closer alignment with normal kinetic velocity profiles. Additionally, the investigators defined an out-of-bounds metric by computing the percentage of cardiac cycle duration during which patient values fell outside the healthy normative envelope bounded by the 5th and 95th percentiles. For volume-time curves, values exceeding the 95th percentile were designated as signs of reduced contractility, whereas derivative deviations were recorded whenever values crossed either boundary.
To assign standardized clinical meaning to these raw geometric distances, the investigators converted the observed separation values into statistical z-scores. They first calculated the individual DVTC and DdVdt values for each of the 371 individuals comprising the normative baseline relative to the cohort median, deriving the normative mean and standard deviation for both parameters. Using these baseline distributions, any individual patient distance measurement was converted into a standard z-score expressing the number of standard deviations the patient curve diverged from the healthy population mean. To verify the numerical stability of this comparative framework, the researchers tested an independent verification cohort of 20 healthy pediatric controls aged 1 day to 26 months who were not involved in the initial model construction. When processed through the identical software pipeline and projected against the normative baseline, the verification subjects demonstrated distance metrics clustering reliably within normal baseline limits with only minor statistical outliers, confirming that the analytical models appropriately recognized healthy ventricular filling and emptying waveforms.
The research team subsequently assessed the clinical utility of the normalized curves by longitudinally analyzing 43 three-dimensional echocardiography datasets obtained from seven pediatric patients diagnosed with complex structural or myocardial conditions. The clinical spectrum included infants presenting with borderline left ventricles, critical aortic stenosis, Shone complex, infiltrative cardiomyopathy secondary to primary systemic hyperoxalosis, and children receiving mechanical support with a left ventricular assist device during weaning evaluations. Superimposing each patient’s normalized volume and velocity curves against the 5th to 95th percentile normative boundaries enabled rapid visual detection of altered ejection fraction, shortened or prolonged systolic and diastolic durations, diminished ejection velocities, and distorted or absent early and late diastolic filling waves, commonly recognized as E-waves and A-waves. In each monitored case, changes observed across serial volume-time waveforms corresponded closely with documented medical interventions and surgical milestones.
Among structural disease cases, four infants designated as patients 002, 008, 009, and 010 had presented with borderline left ventricles either during fetal life or immediately following delivery. Patient 002 presented with critical aortic stenosis and early endocardial fibroelastosis following fetal intervention, undergoing postnatal balloon aortic valvuloplasty on day 3 of life. Serial evaluations on days 4 and 14 revealed persistent depression of ejection fraction, severe deviations across both volume and derivative curves, and marked reduction in peak emptying and filling rates, with distance z-scores falling below the normal range of minus 2 to plus 2. Despite pulmonary artery banding and atrioseptoplasty aimed at a univentricular pathway, curves acquired on days 25 and 26 showed near total functional collapse prior to the infant’s death on day 26. In contrast, patient 008 presented with Shone complex and ventricular septal defect, showing volume curves tracking within normal limits with z-scores remaining within normal boundaries and out-of-bounds percentages below 1 percent, matching an eventual successful biventricular circulation. Similarly, patient 009 exhibited marked improvements in volume-time profiles and derivative velocities following repeated balloon valvuloplasty and subsequent surgical commissurotomy, shifting z-scores from below minus 2 toward normal and positive ranges alongside achieving a successful biventricular repair.
The diagnostic framework also demonstrated distinct utility in tracking metabolic myocardial injury and mechanical circulatory support weaning. In patient PH 32, who had infiltrative cardiomyopathy caused by primary systemic hyperoxalosis, initial recordings displayed preserved ejection fraction alongside reduced peak emptying rates, while standard two-dimensional imaging revealed myocardial thickening. Following the introduction of intensive hemodialysis, subsequent examinations showed progressive recovery of ejection fraction, yet peak emptying rates remained depressed and late filling waves were persistently absent, demonstrating that standard ejection fraction alone failed to expose persistent underlying kinetic abnormalities. In mechanical support assessments involving patients BH1 and BH2 on left ventricular assist devices, reducing pump speed in patient BH1 triggered falling ejection fraction, progressive loss of filling waves, and widening z-score deviations, culminating in an unsuccessful weaning trial. Conversely, patient BH2 maintained stable ejection fractions, normal volume distance z-scores, and manageable derivative changes during pump deceleration, supporting the eventual safe explantation of the assist device.
In evaluating the broader scope of their findings, the authors highlighted several methodological considerations and technical boundaries inherent in pediatric three-dimensional echocardiographic modeling. While the analytical software successfully accommodates datasets derived from either Philips QLab or TomTec analysis tools, inter-vendor software variability remains an acknowledged factor that can influence absolute volumetric computations, prompting the developers to embed vendor-specific selection options directly within the graphical tool. In patients supported by ventricular assist devices, apical cannulas can also disturb acoustic tracking algorithms near the cardiac apex. While acknowledging that these initial clinical demonstrations cannot definitively prove superior therapeutic guidance compared to existing monitoring standards without larger prospective trials and validation against invasive end-diastolic pressure recordings, the researchers concluded that their open-source normalization architecture provides an effective computational foundation for standardizing multi-phase left ventricular functional assessments in pediatric cardiology.
Subject of Research: Three-dimensional echocardiographic left ventricular volume-time curve normalization and comparative analysis in pediatric patients
Article Title: A tool for comparison of 3D echocardiography generated volume-time-curves
Article References: Linden, K., Neidlin, M., Sommer, R., Laser, K. T., & Herberg, U. (2026). A tool for comparison of 3D echocardiography generated volume-time-curves. Pediatric Research. https://doi.org/10.1038/s41390-026-05648-3
Image Credits: AI Generated
DOI: 10.1038/s41390-026-05648-3
Keywords: 3D echocardiography, volume-time curves, left ventricle, pediatric cardiology, cardiac cycle, systolic function, diastolic function, derivative curves, dynamic time warping, z-scores, pediatric research, ventricular mechanics, Fourier series, congenital heart disease, ventricular assist device, hemodialysis, primary hyperoxaluria, aortic stenosis
News Source: Harold Sullivan. (November 27, 2026). Pediatric Researchers Establish 3D Echocardiography Reference Curves for Ventricular Function. Scienmag.